Section search
Enter a keyword or phrase to search all pages in this section:
Advanced searchArchive:
Looking for a previously published document in this section?
| Type: | Medical Device Alert |
|---|---|
| Series No: | MDA/2011/002 |
| Audience: | Healthcare professionals |
| Published: | 6 January 2011 at 11:30 |
| Format: | Electronic only |
| Size: | A4 |
| Pages: | 7 |
| Price: | Free |
| ISBN/ISSN: | None |
| Author: | |
| Copyright: | Crown |
Ref: MDA/2011/002 | Issued: 6 January 2011 at 11:30
If you are in England, please send enquiries about this notice to the MHRA, quoting reference number MDA/2011/002 or 2009/011/004/081/001.
Technical aspects
Ainsley Wickens or Catriona Blake
Medicines & Healthcare products Regulatory Agency
Floor 4
151 Buckingham Palace Road
London
SW1W 9S
Tel: 020 3080 7273 / 7219
Fax: 020 8754 3965
Email: ainsley.wickens@mhra.gsi.gov.uk or catriona.blake@mhra.gsi.gov.uk
Clinical aspects
Jonathan Plumb
Medicines & Healthcare products Regulatory Agency
Floor 4
151 Buckingham Palace Road
London
SW1W 9SZ
Tel: 020 3080 7128
Fax: 020 8754 3965
Email: jonathan.plumb@mhra.gsi.gov.uk
How to report adverse incidents
Please report via our website: Reporting adverse incidents involving medical devices.
Further information about CAS can be found on the Central Alerting System website (external link).
Enquiries and adverse incident reports in Northern Ireland should be addressed to:
Northern Ireland Adverse Incident Centre
Health Estates Investment Group
Room 17
Annex 6
Castle Buildings
Stormont Estate
Dundonald
BT4 3SQ
Tel: 02890 523 704
Fax: 02890 523 900
Email: NIAIC@dhsspsni.gov.uk
Northern Ireland Adverse Incident Centre (NIAIC) (external link)
How to report adverse incidents in Northern Ireland
Please report directly to NIAIC, further information can be found on the NIAIC website (external link).
Further information about SABS can be found on the SABS website (external link).
Incident Reporting and Investigation Centre
Health Facilities Scotland
NHS National Services Scotland
Gyle Square
1 South Gyle Crescent
Edinburgh
EH12 9EB
Tel: 0131 275 7575
Fax: 0131 314 0722
Email: nss.iric@nhs.net
Health Facilities Scotland - Incident Reporting and Investigation Centre (external link).
Enquiries in Wales should be addressed to:
Dr Sara Hayes
Senior Medical Officer
Medical Device Alerts
Welsh Assembly Government
Cathays Park
Cardiff
CF10 3NQ
Tel: 029 2082 3922
Email: Haz-Aic@wales.gsi.gov.uk
Peristeen Anal Irrigation System manufactured by Coloplast Limited.
The following Peristeen product codes contain rectal catheters:
29121 – Peristeen Anal Irrigation System (contains two rectal catheters)
29122 – Accessory Unit (contains 15 rectal catheters and one bag)
29123 – 10 rectal catheters
29126 – Peristeen Anal Irrigation System (contains two rectal catheters - small)
29127 – Accessory Unit (contains 15 rectal catheters – small and one bag)
29128 – 10 rectal catheters – small
Bowel perforation is an extremely rare (less than one in 100,000 uses) complication to anal irrigation.
Recently, there have been some incidents of bowel perforation following insertion of the rectal catheter, which is part of the anal irrigation system.
Bowel perforation is a rare but serious complication of anal irrigation, which often requires surgery to close the perforation or, if necessary, to form a temporary or permanent colostomy. Complications of bowel perforation such as peritonitis or sepsis can be fatal.
The risk of bowel perforation can be reduced by ensuring that patients are clinically assessed for suitability prior to treatment. Patients and carers should receive comprehensive training to ensure that they are competent in the use of the Peristeen Anal Irrigation System before using it unsupervised. The residual risk of perforation should be balanced against the improvement in bowel function and quality of life for each patient.
The risk of bowel perforation has been highlighted in the manufacturer’s revised instructions for use. The MHRA is issuing this Medical Device Alert to bring this issue to wider attention. For information the warnings, contra-indications, precautions and intended use which appear in the most recent IFU for the Peristeen Anal Irrigation System (in packs manufactured after 3 December 2010) are reproduced below:
| WARNINGS |
Anal irrigation procedure should always be carried out with care. Bowel perforation is an extremely rare, but serious and potentially lethal complication to anal irrigation and will require immediate admission to hospital, often requiring surgery.
|
Contact your doctor immediately, if you during or after anal irrigation experience following:
|
This product contains phthalates and should not be used by either children or pregnant or nursing women without consulting a physician. Contains or presence of phthalate: dibutyl phthalate (DBP)
Reuse of the single use rectal catheter may create a potential risk to the user. Reprocessing, cleaning, disinfection and sterilization may compromise product characteristics which in turn create an additional risk of physical harm to or infection of the patient.
| CONTRA-INDICATIONS |
Peristeen Anal Irrigation must not be used in the following situations:
| PRECAUTIONS |
Always consult a physician before starting up the irrigation procedure. If you are heavily constipated an initial and thorough clean-out of your bowels is advisable before starting up the irrigation procedure. Please consult your health care professional.
Peristeen Anal Irrigation is not recommended for:
Special caution must be shown if you have or have had any of the following:
For hygienic reasons the Peristeen Anal Irrigation system must only be used by the same person. Do not share with others.
| Intended Use |
Peristeen Anal Irrigation is for people who suffer from faecal incontinence, chronic constipation or have to spend a long time on bowel management procedures.
|
Please read the whole instruction including warnings, contra-indications and precautions before carrying out the anal irrigation procedure. It is vital for your safety that you consult a physician before starting up the irrigation procedure. We also require that you receive thoroughly instruction from a health care professional before using this product. Your first irrigation must be supervised by a health care professional. Before starting the irrigation procedure, please ensure you have identified which catheter size you are using. The product codes can be found on the catheter packaging.
|
FOR HEALTH CARE PROFESSIONALS
To receive further information as well as training material for Peristeen Anal Irrigation, please access www.coloplast.com for contact information.
Familiarise yourself with the instructions for use (IFU), which have recently been updated.
Ensure that patients (and where appropriate carers):
Before starting Peristeen Anal Irrigation, Coloplast instruct that patients should undergo a medical evaluation by a doctor with appropriate expertise to ensure that they have no conditions that preclude its use or require further investigation.
This MDA has been sent to:
Onward distribution
Please bring this notice to the attention of relevant employees in your establishment. Below is a suggested list of recipients.
Trusts
CAS and SABS (NI) liaison officers for onward distribution to all relevant staff including:
Primary care trusts
CAS liaison officers for onward distribution to all relevant staff including:
Social services
Liaison officers for onward distribution to all relevant staff including:
Independent distribution
Establishments registered with the Care Quality Commission (CQC) (England only)
This alert should be read by:
Establishments registered with OFSTED
This alert should be read by:
Please note: CQC and OFSTED do not distribute these alerts. Sign up to receive MDAs directly from the Department of Health’s Central Alerting System (CAS) by sending an email to: safetyalerts@dh.gsi.gov.uk and requesting this facility.
Sue Frost MPhil, RGN
Senior Market Manager - Peristeen
Coloplast Limited
Tel: 01733 392 030
Mob: 07770 494 726
Email: GBSEF@coloplast.com